NVS Parameter: state plate_loc status


Long Name:

status

Applies to:

  • All

  • Description:

    This state parameter is not normally modified with the 'set' command. The firmware uses this parameter for internal 'housekeeping'.

    This parameter indicates whether a plate is present in the plate location, and what the plate's status is. The following values are possible: 0 = no plate present; 1 = good plate actively in use by an image command; 2 = good plate not actively in use by an image command; 3 = reject plate; 4 = plate on drum when flyoff sensor tripped; 5 = error on plate in conveyor; 6 = plate in conveyor may or may not be present; 7 = double-thickness plate detected on drum.

    Caution: modifying this parameter can lead the recorder to spontaneously reboot when it detects a situation that is "impossible".


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 20

    Notes:


    Partition:

    state

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:49 2002 PST