This state parameter is not normally modified with the 'set' command. The
firmware uses this parameter for internal 'housekeeping'.
This parameter indicates whether a plate is present in the plate location, and
what the plate's status is. The following values are possible: 0 = no plate
present; 1 = good plate actively in use by an image command; 2 = good plate not
actively in use by an image command; 3 = reject plate; 4 = plate on drum when
flyoff sensor tripped; 5 = error on plate in conveyor; 6 = plate in conveyor may
or may not be present; 7 = double-thickness plate detected on drum.
Caution: modifying this parameter can lead the recorder to spontaneously reboot
when it detects a situation that is "impossible".
|