This state parameter is not normally modified with the 'set' command. The
firmware uses this parameter for internal 'housekeeping'.
This parameter indicates whether a plate is present on the left-hand side of
the plate location, and what the plate's status is. The following values are
possible: 0 = no plate present; 1 = good plate actively in use by an image command;
2 = good plate not actively in use by an image command; 3 = reject plate; 4 = plate
on drum when flyoff sensor tripped; 5 = error on plate in conveyor; 6 = plate in conveyor
may or may not be present; 7 = double-thickness plate detected on drum.
Caution: modifying this parameter can lead the recorder to spontaneously reboot