NVS Parameter: proof dvrt


Long Name:

dvac_receiver_thresh

Applies to:

  • Trendsetter_400/800_Proofing

  • Description:

    The level of the drum vaccuum to indicate that a receiver is loaded.

    The threshold should be set so that whenever a receiver is loaded the drum vacuum level is always above the threshold, so include some margin.


    Type:

    word

    Default:

    • 300 (prior to version 1.1) 220 (after version 1.1)

    Range:

    • 0 to 1023 (no units)

    Notes:

    This value is different from one proof size to the other. The factory setting should be:

    • 4Up Proof: 220
    • 8Up Proof: 120


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:50 2002 PST