NVS Parameter: proof ams


Long Name:

active_media_seal

Applies to:

  • Trendsetter_400/800_Proofing

  • Description:

    The physical distance from the edge of the receiver to the starting point of the active media seal routine in (mm). When set to 0, the active media seal routine is disabled. The active media seal routine uses the vacuum roller to apply the pressure onto the donor such that bubbles are pushed out of the sealed media.


    Type:

    uint16

    Default:

    • 0

    Range:

    • 0 to 1200 mm

    Notes:


    Partition:

    cfg

    See Also:

  • Command: proof media seal

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:50 2002 PST