NVS Parameter: sys ast


Long Name:

asynch_series_pause

Applies to:

  • All

  • Description:

    Time to pause in the middle of a retrace when performing an asynchronous series test plot . The carriage will slow down, backup, pause for the given number of seconds (rounded up to the nearest drum rotation), and then accelerated to resume plotting.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 254 [seconds]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: sys asp
  • Command: plot synch

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:57 2002 PST