NVS Parameter: sys hpd


Long Name:

high_pwr_drives_inst

Applies to:

  • Trendsetter_400/800
  • Trendsetter_400/800_Proofing
  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    To achieve higher throughput, new carriage and drum drive systems have been or will be introduced on some products. These new drives allow both the drum and the carriage to accelerate and decelerate more quickly, and also allow the carriage to move at higher speeds.

    This parameter tells the firmware whether these new drive systems are installed.


    Type:

    boolean

    Default:

    • 0 (3230/3244 Trendsetters)
    • 1 (Trendsetter NEWS

    Range:

    • 0 to 1

    Notes:


    Partition:

    cfg

    See Also: