NVS Parameter: sys ntu


Long Name:

nco_tach_update

Applies to:

  • All

  • Description:

    Determines the rate at which the drum speed is measured by the drum speed tracking algorithm. Normally, this parameter is not changed from the default value. Making this parameter too small will seriously affect system performance. Making this parameter too large will lead to PLL errors.


    Type:

    integer

    Default:

    • 60
    • 40 (any machine capable of high speed imaging)

    Range:

    • 0 to 254

    Notes:


    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:58 2002 PST