<Command>
<Name>act chpump</Name>
<Description>
<DescriptionText><text>
Turns the thermal head chiller on or off.  This command does not initiate any
fluid chilling or circulation, that is done with "act chiller".  Normally, whenever
the machine is on, the chiller should also be on.
</text></DescriptionText>
</Description>
<Notes>
<DescriptionText><text>
None.
</text></DescriptionText>
</Notes>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>ThermoFlex</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Syntax>
<NumberedList>
<ListItem><Text>
act chpump on|off
</Text></ListItem>
</NumberedList>
</Syntax>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/act_chiller.xml</LinkAddress><LinkTitle>Command: act chiller</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/chiller.xml</LinkAddress><LinkTitle>Command: chiller</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/chiller_on.xml</LinkAddress><LinkTitle>Command: chiller on</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/chiller_off.xml</LinkAddress><LinkTitle>Command: chiller off</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/chiller_pump_on.xml</LinkAddress><LinkTitle>Command: chiller pump on</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/chiller_pump_off.xml</LinkAddress><LinkTitle>Command: chiller pump off</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:38:42 2008 PST
</Updated>
<Links>
</Links>
</Command>