<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\CommandsStyleSheet.xsl"?>
<Command>
<Name>cass float</Name>
<Description>
<DescriptionText><text>
Controls the cassette air-floatation. On / Off.
</text></DescriptionText>
<DescriptionText><text>
Cal simply turns on the float blower and continuously reports the pressure
read on the Genine 1 onboard vac/pressure sensor.  This sensor should be T
plumbed into the pressure tube comming out of the blower. A value of 5
(VCS_MIN_PLENUM_PRESSURE) is used as a threshold to determine if float is on
or not. Normal float pressure should be 9-20.   NB: first do an ale init or
cass init so that the sensor offset is nulled.
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Syntax>
<NumberedList>
<ListItem><Text>
cass float on|off|cal
</Text></ListItem>
</NumberedList>
</Syntax>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:38:49 2008 PST
</Updated>
<Links>
</Links>
</Command>