<Command>
<Name>laser &lt; laser mode &gt;</Name>
<Description>
<DescriptionText><text>
Controls the laser by communicating with the HC board.
</text></DescriptionText>
<DescriptionText><text>
laser on
</text></DescriptionText>
<DescriptionText><text>
Turns on the laser.
</text></DescriptionText>
<DescriptionText><text>
If the "head lsrmode" is set to 0 or 3 (original mode) then the power setpoint
is the value specified by the hdm NVS parameter "wpower" or "wpowern" depending
on the mode of operation (wide or narrow). When not running a work station
image then selection of wide or narrow depends on the setting of "hdp fnm".
</text></DescriptionText>
<DescriptionText><text>
Starting with head version 1.56 (needs matching MPE code as well) if the
"head lsrmode" is set to 1 or 2 (exposure control mode) then the laser
power setpoint is the hdm NVS parameter "wpowere". Note that this value
is automatically set everytime a machine initiated stroke cal is done. The
calculated wpowere value depends on the "media sens" setting, the "drum
diam", the "hdm ds" setting and the "head swidth" setting.
</text></DescriptionText>
<DescriptionText><text>
Note that the new exposure mode does not use the obsolete "sys es" flag.
Instead, it is controlled instead by the "head lsrmode" parameter.
</text></DescriptionText>
<DescriptionText><text>
Beam positioning is enabled.
</text></DescriptionText>
<DescriptionText><text>
Used for field service and integration.
</text></DescriptionText>
<DescriptionText><text>
laser idle
</text></DescriptionText>
<DescriptionText><text>
Turns on the laser (to idle).
</text></DescriptionText>
<DescriptionText><text>
The power setpoint is hardcoded to 1W. Beam positioning is enabled.
</text></DescriptionText>
<DescriptionText><text>
Used for field service and integration.
</text></DescriptionText>
<DescriptionText><text>
laser standby
</text></DescriptionText>
<DescriptionText><text>
Turns on the laser (to standby).
</text></DescriptionText>
<DescriptionText><text>
The power setpoint is the value specified by the hdm NVS parameter "wpowers".
Beam positioning is enabled.
</text></DescriptionText>
<DescriptionText><text>
Used for field service and integration.
</text></DescriptionText>
<DescriptionText><text>
laser off
</text></DescriptionText>
<DescriptionText><text>
Turns off the laser. On 40W heads also closes the relay to turn on the head.
It is often necessary to issue a "laser off" command to get the head to turn
on after a reset.
</text></DescriptionText>
<DescriptionText><text>
Beam positioning switches to hold mode, i.e., the current in the beam position
actuator is kept constant.
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Availability>
<DescriptionText><text>
This command is available.
</text></DescriptionText>
</Availability>
<Access>
Field
</Access>
<LastModified>
27-Jun-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:24:53 2008 PST
</Updated>
<Links>
</Links>
</Command>