<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40407</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Please remove plate detected on picker
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_ContinuousLoad</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A plate has been detected on the picker, and must be removed.  This could occur during initialization,
at the start of a pick command, or "time picker" command.
</text></DescriptionText>
<DescriptionText><text>
This error may occur in the case of an incorrect vacuum reading.  Use the "picker" command to display
the vacuum reading.  Check the vacuum threshold level ("set mh pvacthresh") to make sure it is above
the no-plate level.
</text></DescriptionText>
<DescriptionText><text>
The sensor name is "AI_PickerVacuum".  It is possible to bypass this sensor temporarily with the "scan" command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
If possible, remove the plate from the picker.  Call the Response Centre for assistance
if necessary.  Select RESUME to continue.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Plate left on picker when machine was reset
</Cause>
<Cause>
Incorrect vacuum reading
</Cause>
<LastModified>
31-MAY-2001
Created.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>