<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40415</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Separator arm timeout: Failed to &lt;Action&gt; sensor. [&lt;I/O name&gt;]
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A timeout occurred while trying to move the separator arms in or out.
</text></DescriptionText>
<DescriptionText><text>
Use the &lt;&lt;picker&gt;&gt; command to display the sensor readings.
</text></DescriptionText>
<DescriptionText><text>
It is possible to bypass the sensors using the &lt;&lt;scan&gt;&gt; command.
</text></DescriptionText>
<DescriptionText><text>
Note: When moving the separator arms out (retracted), the sensor is only checked during
initialization.  After that, they are not checked.  This is because the arms often miss the
microswitches.  We do check that the arms leave the switches properly when moving the arms in.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Faulty cylinder.
</Cause>
<Cause>
Slow cylinder - did not move in the expected time.
</Cause>
<Cause>
Faulty sensor.
</Cause>
<Parameter>
Action -
This is a string that describes how the action timed out, i.e. "leave", "arrive at", etc.
</Parameter>
<Parameter>
I/O name -
This is the standard firmware name of the sensor.
</Parameter>
<LastModified>
22-MAR-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>