<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40426</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: No plates detected in the bay.  The plate may not have been properly loaded by the Preloader
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_ContinuousLoad</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
After the Preloader has finished loading a plate (or plates) into the bay, we check the plate
stack sensors in the bay.  If this indicates that the bay is still empty, this error is reported.
</text></DescriptionText>
<DescriptionText><text>
If there are plates in the bay covering the sensor(s), then maybe the sensor(s) is broken.  Use the
&lt;&lt;picker&gt;&gt; command to check the sensor(s).  The &lt;&lt;scan xxx bon&gt;&gt; command can be used to disable the
sensors.  For Autoloader, the sensor name is AL_SensorPlateStackAway. For Newspaper, the sensor names
are AL_SensorPlateStackHome and AL_SensorPlateStackAway.
</text></DescriptionText>
<DescriptionText><text>
It may be useful to consult the preloader display for more information.
</text></DescriptionText>
<DescriptionText><text>
The preloader status can be checked using the &lt;&lt;preloader&gt;&gt; command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The Preloader did not load a plate properly into the Trendsetter bay.  The sensors on the Trendsetter
indicate that the bay is still emptry.  Check the Preloader display for more information.  If it seems
fine, select RESUME to try again.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Preloader is having trouble loading.
</Cause>
<LastModified>
23-May-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>