<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40740</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: TEC adjust &lt;Current TEC adjust&gt; is too small for this plate size, should be at least &lt;Recommended TEC adjust&gt;
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error indicates that the NVS parameter "mh TECAdjust" is too small for
the plate size being loaded.  If the plate size is very large, then the
trailing edge clamps must be positioned so that they are further on-plate,
to avoid risking a clamp position that is past the park position, which would
result in a collision with the trailing edge backbone and the leading edge
clamp.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><UnnumberedList>
<ListItem><Text>
Make sure that there is sufficient overlap of the trailing edge clamp to fit
</Text></ListItem>
the media on the drum if it is very large.  The mainscan size of the media
minus the trailing edge clamp adjust parameter should not exceed 832.5 mm
for Trendsetter devices.
</UnnumberedList></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The TECAdjust is too small for the mainscan size being used.  If the mainscan
size is very large, you may need to increase the amount the trailing edge clamp
overlaps the plate in order to fit it on the drum.
</Cause>
<Parameter>
Current TEC adjust
The current value of the NVS parameter "mh TECAdjust".
</Parameter>
<Parameter>
Recommended TEC adjust
The recommended value of the NVS parameter "mh TECAdjust" for this plate size.
</Parameter>
<LastModified>
27-Sep-2004
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/mdh_mh_tecadjust.xml</LinkAddress><LinkTitle>PRM: mh tecadjust</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:30 2008 PST
</Updated>
<Links>
</Links>
</Error>