<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40743</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Media has invalid main scan length &lt;MeasuredLength&gt; mm, it is larger than expected &lt;ExpectedLength&gt; mm
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
During loading, the media was measured to be larger than expected.  This may happen if the edge
of the media is seen later than expected, or if the media is still detected on the load ramp
after the drum reaches its expected position for clamping.
</text></DescriptionText>
<DescriptionText><text>
If the media is the correct size, then the load ramp sensor may not be working properly.
Check for any debris blocking the sensor.  If the sensor is clean, check the "mh DistSensorToLEC"
parameter.  It can be calibrated with the &lt;&lt;load calibrate&gt;&gt; command.  If this fails, use the command
&lt;&lt;scan ps_loadramp bon&gt;&gt; in the diagnostic monitor to bypass the sensor to get the customer going
and arrange for field service.
</text></DescriptionText>
<DescriptionText><text>
The sensor status can be read with the &lt;&lt;ramp&gt;&gt; command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Base Trendsetter and Spectrum: Remove the plate on the load ramp and click the "RESUME" button.
The trendsetter will sort things out for about 30 seconds and ask the user to load another plate.
Load a correct-sized plate at this time and hit the load button.
</text></DescriptionText>
<DescriptionText><text>
Trendsetter Autoloader: Remove the plate on the load ramp and click the "Plate Removed" button.
Make sure the correct-sized plates are loaded in the bay, or are being used for manual bypass
loading.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The operator loaded an over-sized plate on the load ramp.
</Cause>
<Cause>
The operator loaded an over-sized plate in the bay.
</Cause>
<Cause>
The load plate sensor is dirty, damaged or misaligned.
</Cause>
<Cause>
The load ramp sensor was not calibrated properly.
</Cause>
<Parameter>
MeasuredLength -
This is the measured media length in mm
</Parameter>
<Parameter>
ExpectedLength -
This is the expected media length in mm
</Parameter>
<LastModified>
20-SEP-2004
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:30 2008 PST
</Updated>
<Links>
</Links>
</Error>