<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40803</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Unload table vacuum timeout:  Failed to achieve vacuum threshold (&lt;Threshold&gt;) within &lt;Timeout&gt; ms (only reached &lt;ActualValue&gt;). [&lt;I/O name&gt;]
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_ContinuousLoad</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A timeout occurred while waiting for the unload table vacuum to cross the threshold.
</text></DescriptionText>
<DescriptionText><text>
This error will generally come up when the unload table cups try to grab the plate, but it could also
occur when releasing the plate if the vacuum level does not drop quickly enough.
</text></DescriptionText>
<DescriptionText><text>
The vacuum level can be checked with the &lt;&lt;table&gt;&gt; command.  The threshold is set with the
"mhauto UvacThresh" and "mhauto UvacDualThresh" parameters.  A command will eventually exist to help
with threshold calibration.
</text></DescriptionText>
<DescriptionText><text>
It is possible to bypass the sensor temporarily with the &lt;&lt;scan&gt;&gt; command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The unload table cup vacuum sensor did not reach the expected threshold
</Cause>
<Cause>
Incorrect threshold value
</Cause>
<Parameter>
Threshold -
This is the threshold value that was not reached.
</Parameter>
<Parameter>
Timeout -
This is the amount of time allowed to reach the threshold.
</Parameter>
<Parameter>
ActualValue -
This is the actual value reached after the timeout.
</Parameter>
<Parameter>
I/O name -
This is the standard firmware name of the sensor.
</Parameter>
<LastModified>
08-JAN-2001
Automated conversion to new FW1 error template.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:31 2008 PST
</Updated>
<Links>
</Links>
</Error>