<ErrorNumber>43007</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: The cabinet has lost power
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
There is no flow in the debris removal system.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that the cabinet is plugged in, the outlet is live, and that you can hear
the blower running.  If you are unable to resolve the problem, contact your local
Customer Service Representative.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Cause 1:  If the green light on top of the cabinet comes on and then goes off without the blower coming on, check the power to the cabinet.
Solution: Make sure the power cable has not come unplugged at the cabinet or the wall. Check that there is power at the wall receptacle.
WARNING:  the UDRC runs off 200-240 VAC, please use appropriate precautions when tracing main power problems.
On some occasions the main power connection to the motor (molex connector inside the UDRC motor enclosure) may have come loose.  Turn the UDRC upside down and remove the bottom cover to gain access to the motor enclosure.
The green light indicates power (coming from the device cable) to the UDRC relay.
</Cause>
<Cause>
Cause 2:  If the green light on top of the cabinet never comes on, the UDRC relay may be broken.
Solution:  The green light itself may be burnt out or have a poor connection.  While this will not cause any functional problem at all, it is important to eliminate this or you risk mis-diagnosing a broken relay.
Reseat cable connection between device and UDRC.  Trace the cables from the green light and check connections, check for voltage on this line when light should be on.
Replace the relay if defective.  Some UDRC disassembly is required to access the relay in the UDRC Power box.
</Cause>
<Cause>
Cause 3:  The cabinet may have over heated.
Solution:  The maximum operating conditions for the cabinet are 32(c (90(f) and 240 volts. If these are met check the cooling air inlet for obstructions. The inlet is located at the bottom front of the cabinet.  After the motor has cooled down, the UDRC will be operational, of course if the cause was not identified, there is a risk of repeat occurrence of this problem.
</Cause>
<LastModified>
07-Jul-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:36 2008 PST
</Updated>
<Links>
</Links>
</Error>