<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>43008</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: The particulate filter is not present or upside down, the lid is not closed, or the data cable is disconnected
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Either the debris cabinet lid is not closed, the data cable is disconnected, or
the debris filters are not properly installed in the cabinet.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that the particulate filter is installed and that it is installed with the
gasket facing up.  Check that a filter spacer is installed and that it is installed
the right way up.  Check that a chemical filter is installed if required.  Check
that the lid is latched properly.  Check that the data cable is connected.  If
you are unable to resolve the problem, contact your local Customer Service
Representative.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Cause 1:  The particulate filter is installed upside down or is not present.
Solution:   Ensure the particulate filter is placed on the spacer and is level, with the open end of the filter upwards.  Ensure spacer is in the correct orientation.  In an L-option cabinet, make sure the spacer is present between the chemical and particulate filters.
</Cause>
<Cause>
Cause 2:  The lid is not closed.
Solution:   Ensure the lid closes securely, without excessive force.
</Cause>
<Cause>
Cause 3:  The spring on the filter detect switch is missing or damaged.
Solution:  Replace the spring (59-3845).
</Cause>
<Cause>
Cause 4:  The filter detect switch is malfunctioning.
Solution:  Test the cabling and/or replace the cables (10-4939) and filter detect switch (15-3431).
</Cause>
<Cause>
Cause 5:  For POC systems only, the data cable may be disconnected.
Solution:  Make sure the cable is connected at both ends.
</Cause>
<LastModified>
07-Jul-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:36 2008 PST
</Updated>
<Links>
</Links>
</Error>