<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>43019</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: The chemical filter has almost expired. Please ensure a replacement filter is on hand
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The usuage information has passed over a the warning usage threshold. The chemical
filter will soon need to be replaced.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Ensure that a new chemical filter is on hand.  You will not be able to continue
imaging when the chemical filter has expired.  There is a label on the back of
the UDRC with the part number of the chemical filter on it.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Cause 1:  The chemical filter is almost full.
Solution:  This is not an error, rather a message to the user to make sure that there is a replacement chemical filter on hand.
See the label on the back of the cabinet or the user manual or the filter itself for filter part number. The filter will only need to be replaced when error 27020 / 43020 (chemical filter full) is given. The time to chemical filter full may be only a few days depending on the type of media, how many plates per day etc.  This message is received when the chemical filter is 90% full.
-Note: Once the filter is full you can no longer image plates until it is replaced.
</Cause>
<LastModified>
07-Jul-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:36 2008 PST
</Updated>
<Links>
</Links>
</Error>