<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>44518</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: The exposure head is not supported
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The exposure head is not supported.
</text></DescriptionText>
<DescriptionText><text>
Typically this happens when a machine configured for a P22 head has a P33 head
installed or a machine configured for a P33 head has a P22 head installed.
To verify the correct imaging head for the device use the MCE command &gt;&gt;config
or &gt;&gt;license. These will indicate if Quantum imaging (P22) is enabled or if the
device is configured for a non-Quantum (P33) head.
</text></DescriptionText>
<DescriptionText><text>
Only Thermal 1.0 / 1.7x, Tfx and Thermal 2 exposure heads are supported.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Install a supported exposure head.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The exposure head that has been installed is not supported by the current
device configuration in firmware.
</Cause>
<LastModified>
26-Jul-2005
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:40 2008 PST
</Updated>
<Links>
</Links>
</Error>