<Error>
<ErrorNumber>44973</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: checksum error in &lt;NVS subsystem&gt; configuration block
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A checksum error was detected in the [head|hdm|hdp|servo_stat] nvs configuration block
in the head. Every time a new value is written to the head, the
appropriate checksum is calculated and written to nvs.
</text></DescriptionText>
<DescriptionText><text>
This error is only reported when the head is initialized (ie. MPE
power up).
</text></DescriptionText>
<DescriptionText><text>
Note that this error is also generated when new head firmware is loaded.
</text></DescriptionText>
<DescriptionText><text>
Check to make sure that all values are present and reasonable in the
[head|hdm|hdp|servo_stat] blocks. If not they may still be stored in the MPE
copy and can be restored with a "head nvs load" command.
</text></DescriptionText>
<DescriptionText><text>
To clear this error, you must type "nvs save [head|hdm|hdp|servo_stat] cfg".
</text></DescriptionText>
<DescriptionText><text>
After upgrading the head firmware from version 1.38 or earlier to version 1.56 or
greater, this error may appear for the servo_stat or 20 Watt configuration block ONLY.
If this is the case, and you are unable to clear it by doing an nvs save, then it is
safe to disregard the error.  It is due to a head/MPE incompatibility, and will not
affect functionality or plot quality in any way.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Faulty head NVS battery.
</Cause>
<Cause>
New head firmware loaded that has new NVS parameters defined.
</Cause>
<Cause>
Noisy 5 Volt line to the head.
</Cause>
<Parameter>
NVS subsystem
Description of the configuration parameter group that has the checksum error.
</Parameter>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:42 2008 PST
</Updated>
<Links>
</Links>
</Error>