<ErrorNumber>45035</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: case temperature high alarm, &lt;Case temperature&gt; C
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Every thirty seconds, the thermal head firmware reads the case temperature and
compares the reading to a threshhold.
</text></DescriptionText>
<DescriptionText><text>
For air-cooled thermal heads ( either head NVS parameter casehigh or caselow is
zero; but not both ), the threshhold is hardcoded to 50 degrees C.  If the
threshhold has been exceeded, the thermal head is shutdown and any plot in
progress is aborted.
</text></DescriptionText>
<DescriptionText><text>
For water-cooled thermal heads ( neither head NVS parameter casehigh or caselow
is zero ), the threshhold is hardcoded to 40 degrees C.  If the threshhold has
been exceeded, the thermal head is shutdown and any plot in progress is aborted.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.30 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Verify the temperature and humidity of the environment local to the machine.
</Cause>
<Cause>
Check the thermal head cooling ( thermal heads are air-cooled or water-cooled ).
Is the water-cooling functioning?
</Cause>
<Parameter>
Case temperature
The temperature that triggered this case temperaure alarm.
</Parameter>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ehi_head_casehigh.xml</LinkAddress><LinkTitle>PRM: head casehigh</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_caselow.xml</LinkAddress><LinkTitle>PRM: head caselow</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:43 2008 PST
</Updated>
<Links>
</Links>
</Error>