<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>45234</ErrorNumber>
<ErrorFamily>Product Support</ErrorFamily>
<ErrorMessage>
PRD: Warning: System Pressure Low
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error indicates that the system pressure is getting low. It is only a warning
and the device will continue to operate. It is not a fault condition, but it does
indicate that the system air pressure has gone below the warning threshold and is
getting close to the fault threshold.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check the air hose connected to the machine and ensure that it has sufficient air pressure.
Check the system pressure gauge on the machine to see the pressure reading.  Adjust
external air supply if necessary.
Check the system air pressure measured by the device, as well as the fault and warning
thresholds by issuing the "system" command.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The system pressure has dropped below the warning level
</Cause>
<Cause>
The system pressure threshold parameter ("prd systhresh") is not set properly
for this machine. The warning threshold is a fixed level (5 psi) above the fault threshold.
Changing the system pressure fault threshold ("prd systhresh") will also change the warning
threshold.
</Cause>
<LastModified>
05-Nov-2004
Created.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:45 2008 PST
</Updated>
<Links>
</Links>
</Error>