<ParameterFamily>EHI</ParameterFamily>
<Syntax>
head diag0
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The first four bits specify the signal sent to pin 1 of the HC board test point
cable accessed via the PD board.
</text></DescriptionText>
<DescriptionText><text>
Setting Signal
</text></DescriptionText>
<DescriptionText><text>
0 focus error
1 lens positioning servo error
2 write laser power servo error
3 beam positioning servo error
</text></DescriptionText>
<DescriptionText><text>
The second four bits specify data stored to the lower half of the second bank
when diag5 &gt; 0.  Note that in order to store focus data, diag1 must be set to
0 as well.
</text></DescriptionText>
<DescriptionText><text>
Storing Data
</text></DescriptionText>
<DescriptionText><text>
0   focus data (stored in swaths)
16  write laser (M2) sensor
32  BP0 sensor
48  BP1 sensor
64  nosepiece sensor
80  diode temperature
96  ambient temperature
112 case temperature
128 humidity
144 LV temperature
160 focus sum
176 focus difference
192 diagnostic port 0 output
208 diagnostic port 1 output
224 focus lens position
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
07-May-2002
</LastModified>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:57 2008 PST
</Updated>
<Links>
</Links>
</Parameter>