<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>EHI</ParameterFamily>
<Syntax>
head fmod
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter affects the performance and stability of the lens positioning
servo. It has been set to 0, and should never be changed in the field.
</text></DescriptionText>
<DescriptionText><text>
This parameter should always be set to 0 except during head alignment in the
factory. When fmod and power are both set to 0 (the normal case) the modulation
is optimally adjusted internally and the focus laser power set by the "hdm sr"
setting. The rest of this description applies only if these values are not set
to 0.
</text></DescriptionText>
<DescriptionText><text>
If fmod is nonzero, it specifies the modulation depth of the light output from
the autofocus laser diode. The focus laser beam is amplitude-modulated to
improve the noise rejection of the optical distance sensor.
</text></DescriptionText>
<DescriptionText><text>
The modulation depth depends on the fpower setting. If fpower is changed, fmod
has to be changed to maintain the same modulation depth.
</text></DescriptionText>
<DescriptionText><text>
The units are not calibrated.
</text></DescriptionText>
<DescriptionText><text>
The output of the optical sensor is proportional to the modulation depth and not
to the average output power of the diode. To increase the amplitude of the
signal emerging from the optical distance sensor, fmod, not fpower, should be
increased.
</text></DescriptionText>
<DescriptionText><text>
If fmod is too large, the sinusoidal modulation becomes clipped, which may
degrade the sensor's performance.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
07-May-2002
</LastModified>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../prm/ehi_head_fpower.xml</LinkAddress><LinkTitle>PRM: head fpower</LinkTitle></Link></li>
<li><Link><LinkAddress>../prm/ehi_hdm_sr.xml</LinkAddress><LinkTitle>PRM: hdm sr</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:57 2008 PST
</Updated>
<Links>
</Links>
</Parameter>