<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>EHI</ParameterFamily>
<Syntax>
head hpslope
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Used in conjunction with the "hpoffset" parameter to convert the raw results of
"head power full" and "head power off" measurements into Watts out of the head.
</text></DescriptionText>
<DescriptionText><text>
The raw reading of the shutter sensor is affected by the "head hpwrgain"
parameter setting so changing this value will require commensurate changes to
"hpslope".
</text></DescriptionText>
<DescriptionText><text>
This value can only be calibrated if an external power meter is available and
hence this parameter should not be changed from its factory setting.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
07-May-2002
</LastModified>
<Notes>
<DescriptionText><text>
Note that the "head power sum" command is the more reliable way to measure
power out of the head with firmware versions greater than 1.5.
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../prm/ehi_head_hpoffset.xml</LinkAddress><LinkTitle>PRM: head hpoffset</LinkTitle></Link></li>
<li><Link><LinkAddress>../prm/ehi_head_hpwrgain.xml</LinkAddress><LinkTitle>PRM: head hpwrgain</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/head_power.xml</LinkAddress><LinkTitle>Command: head power</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:57 2008 PST
</Updated>
<Links>
</Links>
</Parameter>