<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>MPC</ParameterFamily>
<Syntax>
gc focoffset
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Sets the offset between the focus laser and the write laser.  This is required
in order to shift the image to the proper location when imaging POS jobs.  The
seam is detected with the focus laser which leads the write laser by approximately
2mm.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>0 [microns]</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
26-Jan-2004
</LastModified>
<Notes>
<DescriptionText><text>
This value is determined using the GC process during integration, and
should not have to be changed in the field.
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/plot_gc.xml</LinkAddress><LinkTitle>Command: plot gc</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:24:04 2008 PST
</Updated>
<Links>
</Links>
</Parameter>