Tfx Command
foc cal reflect

Description This command finds the media reflectivity required to give a focus sum of approximately 1200 (1000 for firmware < 0.31) for a given receiver gain setting.

Notes Before executing this command the head must be positioned so that the target media is within range of the focus measurement system.

Related Documents COMMAND: foc rcvrgain <receiver gain>
PARAMETER: med <media index> sr
PARAMETER: med <media index> rcvrgain

Applies to: TFX THERMAL2
Access: FIELD
Modified: Thu Aug 30 16:23:11 2007
Updated: Thu Jul 17 02:31:31 2008
Module: FOC