Tfx Command
sys fault state

Description Determine the fault state. System faults will monitor the state of the system and if required, abort plots in progress or block the launching of plots. System faults only represent a fraction of the fault conditions that the exposure head will detect. However, other fault conditions can only be detected while a plot is in progress.

The system faults that will abort plots in progress or block the launching of plots are as follows:
  • Safety Loop
  • Laser Voltage
  • +5 Volts
  • +3 Volts
  • -5 Volts
  • +48 Volts

Note that the monitor command sys fault will display the fault configuration and the monitor command sys fault <point> (on|off) will configure the fault mask's.

Related Documents COMMAND: sys fault (warning|fatal) [<number>]
COMMAND: sys fault [<point> (on|off)]
ERRORCODE: [03536] The safety voltage point is out-of-range
ERRORCODE: [03538] The laser voltage point is out-of-range
ERRORCODE: [03540] The +5V is out-of-range
ERRORCODE: [03542] The +3.3V is out-of-range
ERRORCODE: [03544] The -5V is out-of-range
ERRORCODE: [03546] The +48V is out-of-range

Firmware Notes The monitor command sys fault state corresponds to the API function CEH_FaultState( ) in the CEH API document.

Applies to: TFX
Access: FIELD
Modified: Sat Aug 30 15:41:46 2003
Updated: Thu Jul 17 02:31:30 2008
Module: SYS