Tfx Errorcode
[00905] The power targets (for power curves) are not valid

Service Information The curve points are invalid. These points represent the power values in our power-current curves.

You can display the points by running "dpc points".

The head leaves CreoScitex with the curve points set, and normally these are not changed in the field. This error could be caused by
  • Flash corruption
  • Incorrectly modified parameters

Operator Action Call Service and find out which points are appropriate for your head. As of Sept. 2000 (1W diodes), the points are 150, 200, 250, 300, and 800. These are set by running "dpc points 150 200 250 300 800".

Causes
  • Bad power points in the power curves.

Related Documents COMMAND: dpc points [<power_points>]

Applies to: TFX
Modified: Wed Aug 15 17:04:20 2001
Updated: Thu Jul 17 02:31:29 2008
Module: DPC