Tfx Errorcode
[04918] Redirection must be disabled for negotiation

Service Information The default baud rate of the exposure head is 9600 baud and the default application protocol of the exposure head is Thermal 1.0 / 1.7x compatible. However, the exposure head supports a negotiation algorithm to change the baud rate and application protocol as required. This error code indicates that negotiation was attempted while monitor redirection was enabled. To limit the amount of communication while attempting negotiation, monitor redirection must be disabled.

Operator Action Disable monitor redirection, then re-attempt baud rate or application protocol negotiation.

Causes
  • Monitor redirection is enabled.

Related Documents ERRORCODE: [04919] The requested baud rate is not supported
ERRORCODE: [04920] The requested baud rate is too low
ERRORCODE: [04922] The requested application protocol is not supported