Tfx Errorcode
[03509] The series / system parameter is invalid

Service Information System parameters are the parameters in the exposure head that the host can read and / or write. Series parameters are the parameters in the exposure head that the host can update before plotting ( typically to generate a series plot for diagnostic purposes ).

Normally when the host writes a system parameter, the exposure head will write the system parameter as required. For testing purposes, the user can manually write the system parameter(s) used by the exposure head. This error code indicates that the system parameter either doesn't exist or is read-only.

When the host accesses a system parameter or series parameter, the host must identify the system parameter or series parameter and specify the access type. This error code indicates that either the system parameter or series parameter doesn't exist or the system parameter is read-only or write-only.

Operator Action If the error code is returned in response to a host command, call service. Otherwise, verify the previous monitor command and enter a valid system parameter.

Causes
  • The specified system parameter doesn't exist.
  • The specified system parameter is read-only.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: sys parm access <index> (disable|enable)
COMMAND: sys parm [<index> <value>]

Applies to: TFX
Modified: Fri May 28 15:59:54 2004
Updated: Thu Jul 17 02:31:29 2008
Module: SYS