Tfx Errorcode
[03522] The stroke clock frequency is too high ( > 1250 kHz )

Service Information The exposure head supports a maximum stroke clock frequency of 1.25 MHz. To ensure sufficient margin, the exposure head limits the stroke clock frequency to 1250 kHz. This error code indicates that the host configuration requires a stroke clock frequency that exceeds 1250 kHz.

The stroke clock frequency ( in kHz ) is calculated by multiplying the SCLK's per revolution ( from the system parameter ) by the drum speed ( from the system parameter ) and then dividing by 60 ( to convert the drum speed's minutes to seconds ) and 1000 ( to convert Hz to kHz ).

Since the SCLK's per revolution are determined by the drum diameter and the mainscan DPI, the only solution is to reduce the drum speed.

Operator Action Reduce the drum speed.

Causes
  • The stroke clock frequency is too high.

Related Documents COMMAND: sys parm access <index> (disable|enable)
COMMAND: sys parm [<index> <value>]
COMMAND: vbs enable (<subsystem>|all) <level>

Applies to: TFX
Modified: Fri May 28 15:59:54 2004
Updated: Thu Jul 17 02:31:29 2008
Module: SYS