Tfx Parameter
foc lpos

Description Specifies the position (in microns) of the final objective lens. This position is only used to initialize the held lens position when focus mode is changed to 1, and when a FOC INSTALL ON command is issued.

Lens position is relative to the midpoint of the focus actuator travel.

Type Real

Default Value 0.0000 um

Range -200.0000 to 200.0000 um

Notes On a TFX head the lpos parameter specifies the lens position used during the installation of the head(FOC INSTALL ON). This allows the head to be set up with a reduced range of motion and therefore, lower power dissipation.

Related Documents COMMAND: foc lpos [<lens position>]
COMMAND: foc install (on|off)
PARAMETER: foc lposcal

Applies to: TFX THERMAL2
Access: FIELD
Modified: Wed Aug 29 10:40:59 2007
Updated: Thu Jul 17 02:31:32 2008
Module: FOC