Thermal3 Command
(requires ENG access)
fls read (main|extended) <address> <length>

Variables address Specifies the first address to read from. (Byte offset, word aligned)
length Specifies the number of values to read. (Byte length, word aligned).

Description Read word(s) from the flash. Addresse and legth are in bytes but must be word aligned. Therfore only even addresses and lengths are valid.

For Head Controller versions 1.0- there are two flash sections. The main section is 4Mx8. Therfore valid addresses for this command are even numbers from 0h to 3FFFFEh. The extended section is 32Mx8. Therfore valid addresses for this command are even numbers from 0h to 1FFFFFEh.

For Head Controller versions 2.0+ there is one flash section. This main section is 32Mx8. Therfore valid addresses for this command are even numbers from 0h to 1FFFFFEh.

This is intended as a development tool and should not be used during normal operation.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command fls read (main|extended) <address> <length> does not have an equivalent.

Thermal 2 equivalents:
  • The monitor command fls read (main|extended) <address> <value> is comparable to fls read <address> <value>.

Related Documents COMMAND: fls erase (main|extended) <address> <length>
COMMAND: fls write (main|extended) <address> <value>

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:30 2008
Updated: Wed Jul 16 04:52:20 2008
Module: FLS