| offset
| Specifies the first pulse amplifier to sample from 0 to 463.
|
|
| width
| Specifies the number of pulse amplifiers to sample from 1 to 464.
|
Sample the pulse amplifier(s).
|
|
| A ServiceShell utility will initiate the sampling of the pulse amplifier(s). The firmware will configure a logic analyzer implemented by the hardware to sample the pulse amplifier waveform. When the sampling of the pulse amplifier waveform is complete, the firmware will acquire the pulse amplifier samples from the logic analyzer. After re-formatting the pulse amplifier samples, the firmware will send the pulse amplifier samples through the diagnostic stream to the ServiceShell utility. The ServiceShell utility will then display the pulse amplifier waveform(s) for the user.
|
|
| Note that this diagnostic monitor command will typically only be executed by the ServiceShell utility.
|
|
| This command is not supported by head controller version 2.0 or greater.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command lvd pasample (<offset> <width>|all) [(lvdu|lvdl)] [continuous] does not have an equivalent.
|
|
| Thermal 2 equivalents:
|
|
|
- The monitor command lvd pasample (<offset> <width>|all) [(lvdu|lvdl)] [continuous] does not have an equivalent.
|
COMMAND: lvd pasample off
|