Inform the exposure head of the "Init", "Start", "Pause", "Restart", "Stop" or "Abort" plot command.
|
|
| The "Init" plot command informs the exposure head that a plot has been initiated. The exposure head adjusts the configuration of the exposure head in preparation for the plot.
|
|
| The "Start" plot command informs the exposure head that imaging is about to commence. The exposure head adjusts the configuration of the exposure head in preparation for imaging.
|
|
| The "Stop" plot command informs the exposure head that the plot is complete. The exposure head completes the current plot and configures the default state of the exposure head in preparation for the next plot.
|
|
| The "Abort" plot command informs the exposure head that the plot is being aborted. The exposure head aborts the current plot and configures the default state of the exposure head in preparation for the next plot.
|
|
| The "Pause" and "Restart" plot commands are not supported by the exposure head.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys plot (init|start|pause|restart|stop|abort) does not have an equivalent.
|
|
| Thermal 2 equivalents:
|
|
|
- The monitor command sys plot (init|start|pause|restart|stop|abort) is equivalent to sys plot (init|start|pause|restart|stop|abort).
|
PARAMETER: sys plotenable
|
The monitor command sys plot (init|start|pause|restart|stop|abort) corresponds to the API function CEH_PlotCommand( ) in the CEH API document.
|