Thermal3 Command
vbs list

Description Display the verbose status for all registered subsystems:

<Number>] <Acronym> <HighOp> <Errors> <Debug> <State>

The subsystem number and subsystem acronym identifies the registered subsystems. The monitor command ver list [(name|date)] will display the subsystem number and acronym for all registered subsystems.

The verbose level consists of four masks as follows:
  • HighOp ( bit 0, value of 1 ) enables the display of high operation functions.
  • Errors ( bit 1, value of 2 ) enables the display of error translations.
  • Debug ( bit 2, value of 4 ) enables the display of general debug information.
  • State ( bit 3, value of 8 ) enables the display of state machine information.
Each of the four masks will be identified as one of the following:
  • Enabled
  • Disabled

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command vbs list does not have an equivalent.

Thermal 2 equivalents:
  • The monitor command vbs list is equivalent to vbs list.

Related Documents COMMAND: vbs enable (<subsystem>|all) <level>
COMMAND: vbs disable (<subsystem>|all)
COMMAND: ver list [(name|date)]

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:48 2008
Updated: Wed Jul 16 04:52:21 2008
Module: VBS