Thermal3 Parameter
h1c lrt

Description Configures the time ( in seconds ) the workstation must wait before launching the first image. The delay is initiated after the exposure head has completed initializing.

A "cold" exposure head requires time to allow the beam-pointing to stabilize. Note that the beam-pointing uses a non-switched power supply and thus a safety fault ( and the resulting loss of the laser power supply ) will not affect the beam-pointing stabilization.

Although the workstation is prevented from launching images, test plots and monitor commands are not prevented from launching images and / or enabling the laser. The exposure head will return an error for test plots and monitor commands ( typically for failing to detect the laser ).

Type Integer

Default Value 5 Seconds

Range 0 to 65535 Seconds

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:34 2008
Updated: Wed Jul 16 04:52:23 2008
Module: HIF