Thermal3 Parameter
sys laseranneal

Description Specifies whether light valve annealing is enabled or disabled.

If light valve annealing is enabled ( this NVS parameter is true ), the exposure head will calculate the accrual time for the light valve annealing and will perform light valve annealing when requested by the host.

If light valve annealing is disabled ( this NVS parameter is false ), the exposure head will calculate the accrual time for the light valve annealing but will ignore the light valve annealing request from the host.

Note that either the NVS parameter sys plotenable, the NVS parameter sys bipolarcal or the NVS parameter sys laserenable will disable the write laser and stroke calibration.

Type Boolean

Default Value False

Related Documents COMMAND: sys laser [on|standby|off|anneal]
PARAMETER: sys annealaccrual
PARAMETER: sys annealsetpoint

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:22 2008
Module: SYS