Command: act tfloat


Description:

Controls the float system on the table top of a Thermoflex machine. This pillow of air is used to 'float' a plate while the operator moves it around on the stainless steel surface.


Notes:

None.


Applies To:

  • ThermoFlex

Syntax:

act tfloat on|off


Notes:

Buttons on 3 corners of the ThermoFlex also control the float system, to activate the lights in those buttons when remotely activating the table float systems, use the "act tfloatlt" command.

Use of the table float is found to cause about a 6psi drop in system pressure, this could affect operation of the machine if the total pressure drops below the system pressure threshold set in the "sys" nvs subsystem.


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page


Creo CTP F/W Command Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:04:57 2002 PST