Command: lec


Description:

Moves the leading edge clamp (LEC) actuator bar up or down, or displays its sensor status.

Typing "LEC OFF" raises the LEC actuator bar which closes the Leading Edge Clamps.

Typing "LEC ON" lowers the LEC actuator bar which opens the Leading Edge Clamps (assuming the drum is in the correct LEC position).

If "on" or "off" is not specified, then the status of the LEC actuator sensors will be displayed.


Applies To:

  • Trendsetter_400/800_Auto
  • Trendsetter_400/800_Proofing
  • Trendsetter_400/800
  • Trendsetter_NEWS

Syntax:

lec [on|off]


Notes:


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page


Creo CTP F/W Command Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:05:02 2002 PST