Description: |
Manually loads a plate onto the drum. There are three basic ways to enter this command:
The edge detect position in "plate_loc d" is also reset if the plate size is different that what was last on the drum. An additional parameter, "cal", may be added to the end of any load command to force the automatic calibration of the "al stl" (sensor_to_le) parameter, which is used to measure the plate height. Normally the plate size is verified during a load command by using the table plate sensor and the "al stl" parameter. But when you add the "cal" to the command, you are telling the firmware to trust that the plate size given is identical to the physical plate size, and to set the parameter accordingly. Make sure the carriage is not moving at the time, and the head parameters are not being loaded, or the calibration will be inaccurate because of possible internal firmware latency delays. It is also a good idea to use a plate size between 600 and 1100 mm, so the plate edge is not detected during drum acceleration or deceleration. |
Applies To: |
|
Syntax: |
load [<msz> [<ssz>]][cal] |
Notes: |
See Also: |
Go to CTP Firmware Commands Index Page