Command: table


Description:

Moves & displays the status for the load/unload table on the VLF Trendsetter. For safety reasons the table normally will not automatically move itself, but there are commands here to allow that. This allows for remote diagnostics and cycle testing. Following are the variations of this command:

table up - this will release the table and lock it up once you manually lift it up. To automatically move the table up type "table move up". The plate door will also be opened to prevent any mechanical conflicts.

table down - same as above, but for the down direction. To automatically move the table down type "table move down". If necessary, the plate door is also automatically opened with this command as well.

table vac - this will control & display the status of the table plate vacuum. Type "table vac on" to enable the vacuum and "table vac off" to --you guessed it-- turn it off. "table vac" by itself will display the current vacuum level.

table blow - this will control the table plate blowers. Type "table blow on" to enable the blowers and "table blow off" to --you guessed it-- turn it off. "table blow" will not display the blower status, just listen.

table idle - turns off both ends of the double-ended air solenoid, releasing the table so it will move freely.

table init - initializes the table, safely lowering it and unjamming it from the plate door.

When only "table" is given as the command, the table's sensor status and vacuum pressure level are displayed.


Applies To:

  • Trendsetter_VLF

Syntax:

table [[move] [up|down]|idle|init|[vac [on|off]]]


Notes:


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page