Error Number: 3002


Error Message:

WSCOMM: Parameter syntax error


Applies to:

  • All

Service Information:

The format of a workstation command is not recognized by the recorder. If the workstation is connected and operating correctly, the recorder firmware and workstation software are not compatible.

The workstation should be checked to ensure that it is working properly. Check that the serial interface cable is connected to the correct port on the workstation. If these are ok, the release notes for the workstation software and recorder firmware should be checked for notes on compatiblity. The firmware or software should be upgraded accordingly.


Operator Action:

Record error message and contact Creo Service


Cause:

  • Workstation software malfunctioning
  • Serial interface cable connected to wrong port on workstation.
  • Workstation software and recorder firmware versions are not compatible.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:27 2002 PST