Error Number: 3014


Error Message:

WSCOMM: Abort received when no command active


Applies to:

  • All

Service Information:

An abort command was received from the workstation for an image that is not active. This error can occur when the recorder is reset while imaging, or if the recorder is operated from the diagnostic monitor. This error will also be reported if the recorder and workstation become unsynchronized through other sequences of events.

It is best to re-boot the workstation and recorder if possible. If this error is reported after the recorder was reset and the workstation wasn't, or if the recorder has been operated through the diagnostic monitor, then no further action other than re-booting is necessary. Otherwise, the debug log containing the events leading up to the error should be saved and forwarded to the responsible firmware programmer.


Operator Action:

Re-boot the workstation and recorder. If this error occurs more than once, report the details to Creo service.


Cause:

  • Recorder reset while images are active
  • Recorder operated independantly from workstation through the diagnostic monitor
  • Possible firmware bug

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page