Error Number: 3054


Error Message:

WSCOMM: Workstation issued flush while job was still active. Aborting job.


Applies to:

  • Platesetter_3244
  • Platesetter_VLF
  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS
  • Trendsetter_VLF_Auto

Service Information:

A flush was sent to the device when jobs were still active. This error is reported to the workstation to indicate what is going on. It is a message only, not really an error. It should never cause the machine to suspend.


Operator Action:

This message should only ever appear as a warning message. It means that a flush was sent to the device when jobs were still active. This error is reported to indicate why the job is being aborted.


Cause:

  • Flush sent to the device when jobs were active. Job(s) have been aborted.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:28 2002 PST