Error Number: 4026


Error Message:

MSG: No bay load in progress


Applies to:

  • Platesetter_3244
  • Platesetter_VLF

Service Information:

This error can occur under the following circumstances:

  1. an attempt to abort a load or open bay command when none active
  2. an attempt to resume or inspect a bay when no open or load command is suspended
  3. the bay number of an abort, resume, or inspect doesn't match the active load or open command

Unless the diagnostic monitor interface has recently been used to open or load bays, this error indicates that the workstation and recorder are no longer synchronized. They both should be rebooted. If the diagnostic monitor is being used to open or load bays, make sure that the bay number of the abort, resume, or inspect matches the bay number of the active load or open command..


Operator Action:

Re-boot the workstation and recorder. If this error occurs more than once, report the details to Creo service.


Cause:

  • Recorder and workstation are no longer synchronized.
  • Diagnostic monitor abort, resume, or inspect bay number doesn't match active bay command
  • Diagnostic monitor resume or inspect command issued when bay is not suspended.