Error Message: |
CARRIAGE: Limit switches reporting carriage is both HOME and AWAY |
Applies to: |
|
Service Information: |
The carriage firmware detected that both the HOME and AWAY optical interrupters are tripped. This is likely caused by some problem with the HOME/AWAY board or cable. In fact, if the HA-BP cable is not connected and its cable detection is disabled (i.e. masked), this error will be reported. First check that the HA-BP cable detect is not masked (use the "mask" command). If it was masked, and removing the mask ("mask off ...") caused a HA-BP cable error, the missing cable is the cause of the problem. If no HA-BP cable error is reported, the HA-BP cable should still be inspected and reseated. If the error persists, and no foreign objects are blocking the switches, the HOME/AWAY board, HA-BP cable and ALE should be replaced one at a time. |
Operator Action: |
Check if there are slipsheets, plates, etc stuck around the exposure head. If not, record error message and call Creo service. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page
Go to CTP Firmware Error Search Page