Error Message: |
CARRIAGE: stuck in AWAY position |
Applies to: |
|
Service Information: |
The firmware has attempted to move the carriage off the AWAY switch and failed. Check whether the carriage AWAY switch (optical interrupter) is in fact tripped. The amber "AWAY" light on the HOME/AWAY board should be lit if the switch is tripped. IF THE AWAY SWITCH IS TRIPPED: Try a "carriage home" ("w") command. If the carriage moved but it's still on the switch, repeat the "carriage home" command until it's off the switch. Once off the switch, operation should return to normal. If the carriage did not move, check the red "CM LIMIT" LED on the ALE board and/or the red "LIMIT" LED on the HOME/AWAY board. If they are lit: Check whether the carriage LIMIT switch is tripped (the LIMIT switch is the optical interrupter beside the AWAY switch toward the inside of the board). If the switch is tripped, then the carriage must be moved off this switch by rotating the leadscrew by hand. If the switch is not tripped, there must be a problem with either the HOME/AWAY board, the HA-BP cable, or the ALE. If the carriage did not move and the LIMIT light is not lit, then there is a problem with the carriage drive hardware. Check the following:
If no problem is detected, carriage electrical hardware components should be swapped until a defective one is found, i.e. ALE, leadscrew motor, cables. IF THE AWAY SWITCH IS NOT TRIPPED: Try a "carriage home" ("w") command. If the carriage now moves, it had likely moved too far onto the AWAY switch. To verify that it's working properly now, stop the carriage ("carriage stop" or "q"), move the carriage back onto the switch with "carriage away" and then try a "carriage home" command again. If an error occurs, the HOME/AWAY board and HA-BP cable should be checked or replaced. If the carriage does not move and the "stuck in AWAY position" error is displayed again, either the HOME/AWAY board, the HA-BP cable, or the ALE is causing a false AWAY signal. These should be replaced one at a time until the problem goes away. |
Operator Action: |
Click on RESUME (if it's available) to give the recorder another attempt at moving the carriage (and head). If the error comes up again, click on CANCEL, take the recorder offline at the workstation, and turn the recorder's power on & off again. This will force the system to reinitialize and may clear up the error temporarily. In any case, record the error message and call Creo Service for help as the machine probably needs servicing. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page
Go to CTP Firmware Error Search Page